Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon

Product Details
Customization: Available
Type: Balloon Catheter
Material: PA
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, German
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (20)
  • Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
  • Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
  • Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
  • Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
  • Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
  • Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Certifications
  • Packing & Delivery
  • After Sales Service
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
VSP
Ethylene Oxide Sterilization
Ethylene Oxide Sterilization
Quality Guarantee Period
One Year
Group
Adult
Logo Printing
Without Logo Printing
Transport Package
Box
Specification
Individual package
Trademark
Likang
Origin
China
HS Code
9021900001
Production Capacity
500000

Product Description

Product Description
Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
Semi- Compliant Coronary Spiral Balloon Catheter
Brand: HyperForm
Certification: CE, FDA, NMPA
Supply capacity: 500/day
Program Dilation: Safe and Minimized Balloon Injury
In both plain and scoring balloons, the balloon stress rises linearly as pressure increases, resulting in vessel gain,but also leading to complications such as intimal tear or dissections, particularly in scoring balloon, in which,the stress on the scoring components is significantly higher than on balloon surface.
The VesSpiral, Coronary Spiral Balloon Catheter features spiral raised and depressed segments, At the beginningof intlation, the force is focused orimarily on the raised segments, anchoring the baloon into the esion tissue anddilation at low pressure (4ATM). As the pressure increases, the depressed segments of the spiral expand outward,continuing dilation uniformly on all surrounded intima, until balloon surface fuly flatted which happened aroundRBP(16ATM). This programmed dilation process result in a more balanced distribution of pressure and moreuniform dilation (see figures1&2).
Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
Anti-Slip during Expansion: 
Prevent Balloon Displacement & Vascular lnjury
Balloon displacement during expansion is a common issue in PCl procedures, particularly in difusedatherosclerotic or calcified plagues. Displacement can lead to inaccurate expansion and vascular wall injuryThe grooves on the surface of the spiral balloon, similar to tank continuous tracks, significantly increasefriction between the balloon and the vessel wall, as the pressure increases, these grooves gradually flattenand eventuallyresemble a regular balloon (figure 3).
Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
-Integrated Spiral Element: 
No Risk of Components Falling Off and Excellent Crossabilit.
Diferent to scoring, balloons' manufacturing process that scoring components are made of metal or hard plastic,fixed to the balloon surface through secondary process of welding or adhesive bonding, in Spiral balloon, the Spiralelement material is the same to balloon and integrated during balloon forming process. This unique integratingprocess make the Spiral balloon having the similar low profile as plain balloon(figure 5) but evacuating the risk ofcomponents falling off of scoring balloon's during clinical practice(figure 6).
Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
Safe & Effective Dilation of Spiral Balloon in Preclinical Coronary Arteries
Plain balloons and Spiral balloons (N=6 per group) were randomly implanted into porcine coronary arteries.Coronary artery tissues were extracted at 24 hours, 7days, 28days and 90 days post-implantation. The resultsare: neointima formation occurred in 24hour group(Plain vs. Spiral) is 2 vs.0, 7days group is 4 vs. 1, 21 day groupis 6 vs.2, 90day group is 6 vs.1. These findings indicate that the Spiral balloon causes significantly less damageto blood vessels during dilation than the conventional balloon does(figure 7).
Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
Specification
Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
Lumineer Semi-Compliant PTCA Balloon Catheter
VesSpiral is a semi-compliant rapid exchange catheter with spiral balloon. The spiral elements are integratedand uniformly distributed on the balloon surface during balloon forming. The catheter is used for coronaryarteries dilatation with unique programed dilation mechanism which is more safe and effective than that of both Plain and Scoring balloons.
Plain balloons, being cylindrical shaped and smooth surface, achieve vessel expansion by applyingconsistent pressure to all surround intima tissue as the balloon inflated. Clinically, this consistentdilation often results in vessel intima tearing or dissections, particularly within diffused atheroscleroticlesion or calcified plaques, in which often come with balloon slippage during expansion.
Scoring balloon, their components typically made from metal or rigid plastics and installed afterballoon forming, can caused even worse tissue injury and dissection due to its uneven pressuredistribution, and often came with scoring element fall inside the vessel during dilation, leading to
the significant safety issue.
Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
Certifications
Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon

• CE Marked: The product complies with the European Medical Device Regulation (MDR).
• ISO 13485: Manufactured under a quality management system certified to ISO 13485 standards.
• Other Regional Approvals: Please contact us for specific certification status in your market (e.g., NMPA, FDA, etc.).
Packing & Delivery
Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
Please enter the title here
• Unit Package: Each catheter is individually packed in a sterile, single-use blister tray.
• Inner Packaging: Protected within a sealed Tyvek® pouch.
• Outer Packaging: Shipped in durable cardboard cartons.
• Standard Order Quantity: Please contact us for specific MOQ (Minimum Order Quantity) and custom packaging options.
• Delivery Lead Time: Typically 30-45 days after order confirmation, depending on destination and quantity.
• Shipping Methods: Available via air freight or sea freight to ensure timely and cost-effective delivery to our global partners.
After Sales Service
We are committed to providing comprehensive support to our customers:
•  Technical Support: Our expert team is available to answer procedural questions.
•  Training Materials: We provide access to product manuals and instructional videos.
•  Warranty: Full warranty against manufacturing defects.
•  Efficient Complaint Handling: A dedicated process to address and resolve any product issues promptly.
Company Profile
Coronary Spiral Balloon Catheter Semi-Compliant Rapid Exchange Catheter with Splral Balloon
Likang Xiangyun Biotechnology Co., Ltd.
As an innovation leader in China's medical technology sector, Likang Xiangyun has been committed to providing outstanding solutions for global healthcare since its establishment in 1995. Integrating R&D, production, and trade, we leverage our full industrial chain advantages to become a comprehensive multinational enterprise offering a wide range of products including in vitro diagnostics, cardiovascular disease, neurovascular disease, and peripheral artery disease interventional products and medical equipment services. Our company boasts a top-notch R&D team and modern production bases in China. Core products such as heart stents and drug-coated balloons have obtained CE and MDR certifications, representing the highest level of technology in China's cardiovascular interventional treatment field. Relying on the strategic location of the Xinjiang Khorgos Special Economic Zone, we have established an international marketing network covering the Middle East, South Asia, Central Asia, Russia, and Europe, and achieve efficient cross-border distribution through the "Double West Road" logistics hub. Meanwhile, we maintain in-depth cooperation with top research institutions such as Shanghai Jiao Tong University, continuously promoting technological innovation and have achieved over 30 patent results. In terms of quality control, we strictly adhere to the ISO13485 international standard and have established a cold chain logistics system that meets GSP requirements. In the future, Likang Xiangyun will continue to deepen its market layout along the "Belt and Road" initiative, bringing more high-quality Chinese-made medical products to the world and providing safer and more effective solutions for patients globally.
FAQ
Please enter the title here
Q1: What is the primary clinical use of the HyperForm catheter?
A: It is designed specifically for pre-dilatation before a Drug-Eluting Balloon (DEB) and for post-stent implantation dilatation to ensure optimal stent apposition.

Q2: What makes Lumineer suitable for small vessels or complex lesions?
A:  Its unique taper-tip design and low-profile balloon enhance crossability, while the TransSmooth™ technology ensures superior pushability and trackability in tortuous anatomy.

Q3: What is the minimum guide catheter size required?
A: The HyperForm catheter is compatible with 6F guide catheters and larger.

Q4: What is the shelf life of the product?
A: The shelf life is 24 months from the date of manufacture.

Q5: How do I place an order or request a quote?
A: Please contact our sales team via email or call us at for pricing, availability, and to discuss your specific needs.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now
Product Groups
More